Commit message (Collapse) | Author | Age | Files | Lines | |
---|---|---|---|---|---|
* | simtrace: 7816 UART: Add missing entry in Di table | Sylvain Munaut | 2012-01-26 | 1 | -1/+1 |
| | | | | | | Add missing entry in Fi_table. It's apparently used as '64' in some reader and 'unsupported' in some other. For simtrace I guess we should consider it 64. | ||||
* | Make sure we don't forward power _and_ supply SIM power at the same time | Kevin Redon | 2011-12-18 | 1 | -0/+10 |
| | | | | | | | | The FPF2005 has no reverse voltage blocker, this is why the 3.3V from the LDO flows back into VCC_PHONE. It even damages the chip (so says the datasheet) I corrected the double power source problem by disabling the LDO (see patch), but still 1.8V does not work and 3.0-3.3V is used. I have to look for other reasons. | ||||
* | Fix fi/di calculation for certain mobiles like GT-S770 or HTC Raphael | Bjoern Kerler | 2011-10-21 | 1 | -3/+3 |
| | | | | | There were some mistakes while copying the tables from ISO 7816-3, and also a quite old version of 7816-3 was used. | ||||
* | SIMTRACE: ISO7816: Deal with ATR that don't have historical bytesv0.2 | Harald Welte | 2011-08-16 | 1 | -11/+21 |
| | | | | | In case there are no historical bytes, we immediately transition from the last TD byte into the WAIT_TCK or WAIT_APDU state. | ||||
* | ISO7816: Properly handle T=0 only cards without TCK in ATR | Harald Welte | 2011-08-16 | 1 | -1/+13 |
| | |||||
* | SIMTRACE UART: Reset error status on error related IRQ | Harald Welte | 2011-08-15 | 1 | -0/+9 |
| | | | | | This prevents an IRQ-flood after a parity or overrun error, which in turn would cause a watchdog reset. | ||||
* | simtrace UART: set INACK flag to make sure we ignore any parity error | Harald Welte | 2011-08-15 | 1 | -3/+3 |
| | | | | | | | As a SIM card tracer, we want to remain completely passive and thus not signal back parity errors with the ISO 7816 NACK. The UART INACK flag does exactly that... | ||||
* | DFU: add third 'alternate configuration' for RAM load | Harald Welte | 2011-07-30 | 2 | -0/+2 |
| | | | | | This will allow us to load code directly into RAM without going through flash. | ||||
* | simtrace: add some early spi flash utility routines | Harald Welte | 2011-07-30 | 2 | -0/+224 |
| | | | | This also adds a new 'main_factory' target for simtrace | ||||
* | simtrace: initialize sniffer mode right after start-up | Harald Welte | 2011-06-30 | 1 | -18/+22 |
| | |||||
* | simtrace: switch VCC_SIM into output mode, as we use it to supply Vcc | Harald Welte | 2011-06-21 | 1 | -2/+8 |
| | | | | | | This is just a temp rework in the 1st generation prototype, as the bus switch has too high resistance for passing throuhg Vcc from the phone to the SIM. | ||||
* | simtrace: add VCC_PHINE IRQ detection | Harald Welte | 2011-06-21 | 1 | -0/+19 |
| | |||||
* | simtrace: introduce mode sniffer / mitm switching | Harald Welte | 2011-06-17 | 2 | -6/+50 |
| | |||||
* | simtrace: add support for the analog bus switch | Harald Welte | 2011-06-16 | 3 | -1/+93 |
| | |||||
* | update USB strings (company name and some copy+paste mistakes) | Harald Welte | 2011-06-15 | 2 | -3/+3 |
| | |||||
* | typo: Fix typo, transform reqyests to requests. | Holger Hans Peter Freyther | 2011-01-31 | 1 | -1/+1 |
| | |||||
* | add missing usb_strings_dfu.txt file to simtrace directory | Harald Welte | 2010-12-09 | 1 | -0/+5 |
| | |||||
* | simtrace: Make sure ATR is sent in its own RCTX and we re-allocate in time | Harald Welte | 2010-11-21 | 1 | -1/+11 |
| | |||||
* | simtrace: fix problems causing bogus waiting time expirations | Harald Welte | 2010-11-18 | 1 | -1/+5 |
| | |||||
* | simtrace: Introduce code for proper handling of PTS / PPS | Harald Welte | 2010-11-18 | 1 | -12/+148 |
| | |||||
* | simtrace: add TC based waiting time counter, signal ATR / expiry via USB | Harald Welte | 2010-11-18 | 5 | -78/+292 |
| | |||||
* | simtrace: introduce RST pin handling | Harald Welte | 2010-11-14 | 1 | -12/+32 |
| | |||||
* | Initial version of a SAM7 USART based ISO7816-3 T=0 sniffer | Harald Welte | 2010-11-14 | 3 | -0/+503 |